Module Definition
dashboard | hierarchy | modlist | groups | tests | asserts

Module : spid_jedec
SCORELINECONDTOGGLEFSMBRANCHASSERT
99.38 100.00 100.00 100.00 96.88 100.00

Source File(s) :
/workspaces/repo/scratch/os_regression_2024_09_17/spi_device_2p-sim-vcs/default/sim-vcs/../src/lowrisc_ip_spi_device_0.1/rtl/spid_jedec.sv

Module self-instances :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
tb.dut.u_jedec 99.38 100.00 100.00 100.00 96.88 100.00



Module Instance : tb.dut.u_jedec

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
99.38 100.00 100.00 100.00 96.88 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
99.38 100.00 100.00 100.00 96.88 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
92.52 95.20 84.31 97.00 90.62 95.45 dut


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
no children


Since this is the module's only instance, the coverage report is the same as for the module.
Line Coverage for Module : spid_jedec
Line No.TotalCoveredPercent
TOTAL4747100.00
CONT_ASSIGN6511100.00
ALWAYS7344100.00
CONT_ASSIGN7911100.00
ALWAYS8344100.00
ALWAYS9155100.00
ALWAYS10188100.00
ALWAYS12144100.00
CONT_ASSIGN12511100.00
ALWAYS13233100.00
ALWAYS1381616100.00

64 logic unused_cmd_info; 65 1/1 assign unused_cmd_info = ^{cmd_info_i , cmd_info_idx_i}; Tests: T1 T2 T3  66 67 ////////////// 68 // Datapath // 69 ////////////// 70 71 // Jedec latch 72 always_ff @(posedge clk_i or negedge rst_ni) begin 73 2/2 if (!rst_ni) jedec <= '{default: '0}; Tests: T1 T2 T3  | T1 T2 T3  74 2/2 else if (cmd_sync_pulse_i) jedec <= sys_jedec_i; Tests: T13 T14 T15  | T13 T14 T15  MISSING_ELSE 75 end 76 77 // If num_cc is non-zero, the logic shall return CC first 78 logic cc_needed; 79 1/1 assign cc_needed = |jedec.num_cc; Tests: T1 T2 T3  80 81 logic [7:0] cc_count; 82 always_ff @(posedge clk_i or negedge rst_ni) begin 83 2/2 if (!rst_ni) cc_count <= '0; Tests: T1 T2 T3  | T1 T2 T3  84 1/1 else if (st_q == StCC && outclk_p2s_sent_i) begin Tests: T13 T14 T15  85 1/1 cc_count <= cc_count + 1'b 1; Tests: T104 T65 T54  86 end MISSING_ELSE 87 end 88 89 // Output to Parallel-to-Serial 90 always_ff @(posedge clk_out_i or negedge rst_out_ni) begin 91 1/1 if (!rst_out_ni) begin Tests: T1 T2 T3  92 1/1 outclk_p2s_valid_o <= 1'b 0; Tests: T1 T2 T3  93 1/1 outclk_p2s_byte_o <= 8'h 0; Tests: T1 T2 T3  94 end else begin 95 1/1 outclk_p2s_valid_o <= p2s_valid; Tests: T13 T14 T15  96 1/1 outclk_p2s_byte_o <= p2s_byte; Tests: T13 T14 T15  97 end 98 end 99 100 always_comb begin : p2s_byte_logic 101 1/1 p2s_byte = 8'h 0; Tests: T1 T2 T3  102 103 1/1 if (st_q == StIdle) begin Tests: T1 T2 T3  104 // Manufacturer ID always 105 1/1 p2s_byte = (cc_needed) ? jedec.cc : jedec.jedec_id; Tests: T1 T2 T3  106 1/1 end else if (st_q == StCC) begin Tests: T104 T65 T53  107 1/1 p2s_byte = jedec.cc; Tests: T104 T65 T54  108 1/1 end else if (st_q == StJedecId) begin Tests: T65 T53 T54  109 1/1 p2s_byte = jedec.jedec_id; Tests: T65 T53 T54  110 end else begin 111 // based on byte_sel_q 112 // End of the transfer but host keep toggles SCK. Sending out 0 always 113 1/1 p2s_byte = (byte_sel_q >= 2'b 10) ? 8'h 0 : Tests: T65 T53 T54  114 (byte_sel_q == 2'b 01) ? jedec.device_id[15:8] : 115 jedec.device_id[7:0] ; 116 end 117 end : p2s_byte_logic 118 119 // Byte selection 120 always_ff @(posedge clk_i or negedge rst_ni) begin : byte_sel_latch 121 2/2 if (!rst_ni) byte_sel_q <= 2'h 0; // select manufacturer id Tests: T1 T2 T3  | T1 T2 T3  122 2/2 else if (next_byte) byte_sel_q <= byte_sel_d; Tests: T13 T14 T15  | T65 T53 T54  MISSING_ELSE 123 end : byte_sel_latch 124 125 1/1 assign byte_sel_d = (byte_sel_q == 2'b 10) ? 2'b 10 : byte_sel_q + 1'b 1; Tests: T1 T2 T3  126 127 /////////// 128 // State // 129 /////////// 130 131 always_ff @(posedge clk_i or negedge rst_ni) begin : state_latch 132 2/2 if (!rst_ni) st_q <= StIdle; Tests: T1 T2 T3  | T1 T2 T3  133 1/1 else st_q <= st_d; Tests: T13 T14 T15  134 end : state_latch 135 136 `ASSERT_KNOWN(JedecStKnown_A, st_q) 137 always_comb begin : next_state_logic 138 1/1 st_d = st_q; Tests: T1 T2 T3  139 140 1/1 p2s_valid = 1'b 0; Tests: T1 T2 T3  141 1/1 next_byte = 1'b 0; Tests: T1 T2 T3  142 143 1/1 unique case (st_q) Tests: T1 T2 T3  144 StIdle: begin 145 1/1 if (sel_dp_i == DpReadJEDEC) begin Tests: T1 T2 T3  146 1/1 st_d = (cc_needed) ? StCC : StJedecId ; Tests: T104 T65 T53  147 148 // Send out the dat 149 1/1 p2s_valid = 1'b 1; Tests: T104 T65 T53  150 end MISSING_ELSE 151 end 152 153 StCC: begin 154 155 // cc_count is increased by 1 when outclk_p2s_sent_i is asserted 156 // outclk_p2s_sent_i asserts at the 7th beat, not 8th beat. When 157 // cc_count reaches to num_cc, it is the end of a byte transaction in 158 // SCK input clock domain. So, that time state machine moves to 159 // JedecId 160 1/1 if (cc_count == jedec.num_cc) begin Tests: T104 T65 T54  161 1/1 st_d = StJedecId; Tests: T65 T54 T52  162 end MISSING_ELSE 163 164 1/1 p2s_valid = 1'b 1; Tests: T104 T65 T54  165 end 166 167 StJedecId: begin 168 1/1 if (outclk_p2s_sent_i) begin Tests: T65 T53 T54  169 1/1 st_d = StDevId; Tests: T65 T53 T54  170 end MISSING_ELSE 171 172 1/1 p2s_valid = 1'b 1; Tests: T65 T53 T54  173 end 174 175 StDevId: begin 176 // TERMINAL_STATE 177 178 // Sends data 179 1/1 p2s_valid = 1'b 1; Tests: T65 T53 T54  180 181 1/1 if (outclk_p2s_sent_i) begin Tests: T65 T53 T54  182 1/1 next_byte = 1'b 1; Tests: T65 T53 T54  183 end MISSING_ELSE 184 end 185 186 default: begin 187 st_d = StIdle;

Cond Coverage for Module : spid_jedec
TotalCoveredPercent
Conditions2929100.00
Logical2929100.00
Non-Logical00
Event00

 LINE       84
 EXPRESSION ((st_q == StCC) && outclk_p2s_sent_i)
             -------1------    --------2--------
-1--2-StatusTests
01CoveredT65,T53,T54
10CoveredT104,T65,T54
11CoveredT104,T65,T54

 LINE       84
 SUB-EXPRESSION (st_q == StCC)
                -------1------
-1-StatusTests
0CoveredT13,T14,T15
1CoveredT104,T65,T54

 LINE       103
 EXPRESSION (st_q == StIdle)
            --------1-------
-1-StatusTests
0CoveredT104,T65,T53
1CoveredT1,T2,T3

 LINE       105
 EXPRESSION (cc_needed ? jedec.cc : jedec.jedec_id)
             ----1----
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT15,T16,T17

 LINE       106
 EXPRESSION (st_q == StCC)
            -------1------
-1-StatusTests
0CoveredT65,T53,T54
1CoveredT104,T65,T54

 LINE       108
 EXPRESSION (st_q == StJedecId)
            ---------1---------
-1-StatusTests
0CoveredT65,T53,T54
1CoveredT65,T53,T54

 LINE       113
 EXPRESSION ((byte_sel_q >= 2'b10) ? 8'b0 : ((byte_sel_q == 2'b1) ? jedec.device_id[15:8] : jedec.device_id[7:0]))
             ----------1----------
-1-StatusTests
0CoveredT65,T53,T54
1CoveredT65,T53,T54

 LINE       113
 SUB-EXPRESSION ((byte_sel_q == 2'b1) ? jedec.device_id[15:8] : jedec.device_id[7:0])
                 ----------1---------
-1-StatusTests
0CoveredT65,T53,T54
1CoveredT65,T53,T54

 LINE       113
 SUB-EXPRESSION (byte_sel_q == 2'b1)
                ----------1---------
-1-StatusTests
0CoveredT65,T53,T54
1CoveredT65,T53,T54

 LINE       125
 EXPRESSION ((byte_sel_q == 2'b10) ? 2'b10 : ((byte_sel_q + 1'b1)))
             ----------1----------
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT65,T53,T54

 LINE       125
 SUB-EXPRESSION (byte_sel_q == 2'b10)
                ----------1----------
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT65,T53,T54

 LINE       145
 EXPRESSION (sel_dp_i == DpReadJEDEC)
            ------------1------------
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT104,T65,T53

 LINE       146
 EXPRESSION (cc_needed ? StCC : StJedecId)
             ----1----
-1-StatusTests
0CoveredT65,T53,T54
1CoveredT104,T65,T54

 LINE       160
 EXPRESSION (cc_count == jedec.num_cc)
            -------------1------------
-1-StatusTests
0CoveredT104,T65,T54
1CoveredT65,T54,T52

FSM Coverage for Module : spid_jedec
Summary for FSM :: st_q
TotalCoveredPercent
States 4 4 100.00 (Not included in score)
Transitions 4 4 100.00
Sequences 0 0

State, Transition and Sequence Details for FSM :: st_q
statesLine No.CoveredTests
StCC 146 Covered T104,T65,T54
StDevId 169 Covered T65,T53,T54
StIdle 103 Covered T1,T2,T3
StJedecId 146 Covered T65,T53,T54


transitionsLine No.CoveredTests
StCC->StJedecId 161 Covered T65,T54,T52
StIdle->StCC 146 Covered T104,T65,T54
StIdle->StJedecId 146 Covered T65,T53,T54
StJedecId->StDevId 169 Covered T65,T53,T54



Branch Coverage for Module : spid_jedec
Line No.TotalCoveredPercent
Branches 32 31 96.88
TERNARY 125 2 2 100.00
IF 73 3 3 100.00
IF 83 3 3 100.00
IF 91 2 2 100.00
IF 103 7 7 100.00
IF 121 3 3 100.00
IF 132 2 2 100.00
CASE 143 10 9 90.00


125 assign byte_sel_d = (byte_sel_q == 2'b 10) ? 2'b 10 : byte_sel_q + 1'b 1; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T65,T53,T54
0 Covered T1,T2,T3


73 if (!rst_ni) jedec <= '{default: '0}; -1- ==> 74 else if (cmd_sync_pulse_i) jedec <= sys_jedec_i; -2- ==> MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T13,T14,T15
0 0 Covered T13,T14,T15


83 if (!rst_ni) cc_count <= '0; -1- ==> 84 else if (st_q == StCC && outclk_p2s_sent_i) begin -2- 85 cc_count <= cc_count + 1'b 1; ==> 86 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T104,T65,T54
0 0 Covered T13,T14,T15


91 if (!rst_out_ni) begin -1- 92 outclk_p2s_valid_o <= 1'b 0; ==> 93 outclk_p2s_byte_o <= 8'h 0; 94 end else begin 95 outclk_p2s_valid_o <= p2s_valid; ==>

Branches:
-1-StatusTests
1 Covered T1,T2,T3
0 Covered T13,T14,T15


103 if (st_q == StIdle) begin -1- 104 // Manufacturer ID always 105 p2s_byte = (cc_needed) ? jedec.cc : jedec.jedec_id; -2- ==> ==> 106 end else if (st_q == StCC) begin -3- 107 p2s_byte = jedec.cc; ==> 108 end else if (st_q == StJedecId) begin -4- 109 p2s_byte = jedec.jedec_id; ==> 110 end else begin 111 // based on byte_sel_q 112 // End of the transfer but host keep toggles SCK. Sending out 0 always 113 p2s_byte = (byte_sel_q >= 2'b 10) ? 8'h 0 : -5- ==> 114 (byte_sel_q == 2'b 01) ? jedec.device_id[15:8] : -6- ==> ==>

Branches:
-1--2--3--4--5--6-StatusTests
1 1 - - - - Covered T15,T16,T17
1 0 - - - - Covered T1,T2,T3
0 - 1 - - - Covered T104,T65,T54
0 - 0 1 - - Covered T65,T53,T54
0 - 0 0 1 - Covered T65,T53,T54
0 - 0 0 0 1 Covered T65,T53,T54
0 - 0 0 0 0 Covered T65,T53,T54


121 if (!rst_ni) byte_sel_q <= 2'h 0; // select manufacturer id -1- ==> 122 else if (next_byte) byte_sel_q <= byte_sel_d; -2- ==> MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T65,T53,T54
0 0 Covered T13,T14,T15


132 if (!rst_ni) st_q <= StIdle; -1- ==> 133 else st_q <= st_d; ==>

Branches:
-1-StatusTests
1 Covered T1,T2,T3
0 Covered T13,T14,T15


143 unique case (st_q) -1- 144 StIdle: begin 145 if (sel_dp_i == DpReadJEDEC) begin -2- 146 st_d = (cc_needed) ? StCC : StJedecId ; -3- ==> ==> 147 148 // Send out the dat 149 p2s_valid = 1'b 1; 150 end MISSING_ELSE ==> 151 end 152 153 StCC: begin 154 155 // cc_count is increased by 1 when outclk_p2s_sent_i is asserted 156 // outclk_p2s_sent_i asserts at the 7th beat, not 8th beat. When 157 // cc_count reaches to num_cc, it is the end of a byte transaction in 158 // SCK input clock domain. So, that time state machine moves to 159 // JedecId 160 if (cc_count == jedec.num_cc) begin -4- 161 st_d = StJedecId; ==> 162 end MISSING_ELSE ==> 163 164 p2s_valid = 1'b 1; 165 end 166 167 StJedecId: begin 168 if (outclk_p2s_sent_i) begin -5- 169 st_d = StDevId; ==> 170 end MISSING_ELSE ==> 171 172 p2s_valid = 1'b 1; 173 end 174 175 StDevId: begin 176 // TERMINAL_STATE 177 178 // Sends data 179 p2s_valid = 1'b 1; 180 181 if (outclk_p2s_sent_i) begin -6- 182 next_byte = 1'b 1; ==> 183 end MISSING_ELSE ==> 184 end 185 186 default: begin 187 st_d = StIdle; ==>

Branches:
-1--2--3--4--5--6-StatusTests
StIdle 1 1 - - - Covered T104,T65,T54
StIdle 1 0 - - - Covered T65,T53,T54
StIdle 0 - - - - Covered T1,T2,T3
StCC - - 1 - - Covered T65,T54,T52
StCC - - 0 - - Covered T104,T65,T54
StJedecId - - - 1 - Covered T65,T53,T54
StJedecId - - - 0 - Covered T65,T53,T54
StDevId - - - - 1 Covered T65,T53,T54
StDevId - - - - 0 Covered T65,T53,T54
default - - - - - Not Covered


Assert Coverage for Module : spid_jedec
TotalAttemptedPercentSucceeded/MatchedPercent
Assertions 1 1 100.00 1 100.00
Cover properties 0 0 0
Cover sequences 0 0 0
Total 1 1 100.00 1 100.00




Assertion Details

NameAttemptsReal SuccessesFailuresIncomplete
JedecStKnown_A 140189703 110429241 0 0


JedecStKnown_A
NameAttemptsReal SuccessesFailuresIncomplete
Total 140189703 110429241 0 0
T13 1362 1362 0 0
T14 12966 12966 0 0
T15 56310 55596 0 0
T16 29086 29086 0 0
T17 45084 44664 0 0
T19 16479 16479 0 0
T21 33897 33664 0 0
T22 38186 37584 0 0
T23 24346 24204 0 0
T24 0 41932 0 0
T27 360 0 0 0

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%