dashboard | hierarchy | modlist | groups | tests | asserts

Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_12

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_13

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_14

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_15

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_0

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_1

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_2

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_3

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_4

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_5

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_6

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_7

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_0

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_1

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
95.24 85.71 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
96.30 88.89 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_2

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_3

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
95.24 85.71 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
96.30 88.89 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_4

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_5

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_6

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
95.24 85.71 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
96.30 88.89 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_7

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
95.24 85.71 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
96.30 88.89 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_mode_0

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_filter_0

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_miodio_0

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_mode_1

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_filter_1

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_miodio_1

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_mode_2

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_filter_2

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_miodio_2

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_mode_3

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_filter_3

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_miodio_3

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.25 99.77 97.22 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00

Go back
Module Instances:
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_12
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_13
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_14
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_15
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_0
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_1
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_2
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_3
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_4
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_5
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_6
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_7
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_0
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_1
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_2
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_3
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_4
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_5
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_6
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_7
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_mode_0
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_filter_0
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_miodio_0
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_mode_1
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_filter_1
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_miodio_1
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_mode_2
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_filter_2
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_miodio_2
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_mode_3
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_filter_3
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_miodio_3
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_12
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T7 T20 T74  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T7 T20 T74  65 1/1 assign qe = wr_en; Tests: T7 T20 T74  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T158 T408 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_12
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT7,T20,T74

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_12
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T7,T20,T74
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T7,T20,T74
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_13
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T7 T20 T74  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T7 T20 T74  65 1/1 assign qe = wr_en; Tests: T7 T20 T74  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T160 T180 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_13
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT7,T20,T74

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_13
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T7,T20,T74
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T7,T20,T74
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_14
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T7 T20 T21  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T7 T20 T21  65 1/1 assign qe = wr_en; Tests: T7 T20 T21  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T7 T20 T160 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_14
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT7,T20,T21

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_14
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T7,T20,T21
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T7,T20,T21
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_15
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T7 T20 T74  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T7 T20 T74  65 1/1 assign qe = wr_en; Tests: T7 T20 T74  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T7 T74 T407 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_15
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT7,T20,T74

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_dio_pad_sleep_mode_15
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T7,T20,T74
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T7,T20,T74
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_0
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T421 T433 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_0
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_0
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_1
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T407 T158 T160 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_1
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T458,T407

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_1
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T458,T407
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_2
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T160 T180 T163 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_2
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_2
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_3
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T158 T160 T180 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_3
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_3
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_4
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T407 T160 T161 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_4
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_4
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_5
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T407 T158 T160 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_5
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T481,T407

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_5
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T481,T407
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_6
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T160 T408 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_6
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_6
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_7
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T97 T98  65 1/1 assign qe = wr_en; Tests: T74 T97 T98  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T158 T160 T180 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_7
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_regwen_7
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_0
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T6 T25 T29  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T6 T25 T29  65 1/1 assign qe = wr_en; Tests: T6 T25 T29  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T6 T25 T29 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_0
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT6,T25,T29

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_0
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T6,T25,T29
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T6,T25,T29
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_1
Line No.TotalCoveredPercent
TOTAL7685.71
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN72100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T158 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T158 T160  65 1/1 assign qe = wr_en; Tests: T74 T158 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 0/1 ==> assign qs = q;

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_1
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T158,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_1
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T158,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T158,T160
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_2
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T74 T407  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T74 T407  65 1/1 assign qe = wr_en; Tests: T26 T74 T407  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_2
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T74,T407

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_2
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T74,T407
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T74,T407
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_3
Line No.TotalCoveredPercent
TOTAL7685.71
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN72100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T158  65 1/1 assign qe = wr_en; Tests: T74 T407 T158  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 0/1 ==> assign qs = q;

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_3
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_3
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_4
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T27 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T27 T158  65 1/1 assign qe = wr_en; Tests: T74 T27 T158  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T27 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_4
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T27,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_4
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T27,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T27,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_5
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T77 T78 T79  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T77 T78 T79  65 1/1 assign qe = wr_en; Tests: T77 T78 T79  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T77 T78 T79 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_5
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT77,T78,T79

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_5
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T77,T78,T79
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T77,T78,T79
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_6
Line No.TotalCoveredPercent
TOTAL7685.71
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN72100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T407 T158 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T407 T158 T160  65 1/1 assign qe = wr_en; Tests: T407 T158 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 0/1 ==> assign qs = q;

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_6
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT407,T158,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_6
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T407,T158,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T407,T158,T160
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_7
Line No.TotalCoveredPercent
TOTAL7685.71
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN72100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T158  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T158  65 1/1 assign qe = wr_en; Tests: T74 T407 T158  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 0/1 ==> assign qs = q;

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_7
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T158

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_en_7
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T158
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T158
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_mode_0
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T6 T25 T29  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T6 T25 T29  65 1/1 assign qe = wr_en; Tests: T6 T25 T29  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T6 T84 T74 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_mode_0
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT6,T25,T29

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_mode_0
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T6,T25,T29
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T6,T25,T29
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_filter_0
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T6 T25 T29  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T6 T25 T29  65 1/1 assign qe = wr_en; Tests: T6 T25 T29  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T158 T160 T163 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_filter_0
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT6,T25,T29

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_filter_0
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T6,T25,T29
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T6,T25,T29
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_miodio_0
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T6 T25 T29  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T6 T25 T29  65 1/1 assign qe = wr_en; Tests: T6 T25 T29  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T6 T84 T85 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_miodio_0
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT6,T25,T29

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_0_miodio_0
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T6,T25,T29
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T6,T25,T29
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_mode_1
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T160  65 1/1 assign qe = wr_en; Tests: T74 T407 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T407 T160 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_mode_1
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_mode_1
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T160
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_filter_1
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T160  65 1/1 assign qe = wr_en; Tests: T74 T407 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T407 T408 T163 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_filter_1
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_filter_1
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T160
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_miodio_1
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T160  65 1/1 assign qe = wr_en; Tests: T74 T407 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T160 T163 T161 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_miodio_1
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_1_miodio_1
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T160
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_mode_2
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T74 T407  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T74 T407  65 1/1 assign qe = wr_en; Tests: T26 T74 T407  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T158 T180 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_mode_2
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T74,T407

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_mode_2
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T74,T407
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T74,T407
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_filter_2
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T74 T407  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T74 T407  65 1/1 assign qe = wr_en; Tests: T26 T74 T407  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T408 T421 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_filter_2
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T74,T407

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_filter_2
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T74,T407
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T74,T407
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_miodio_2
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T74 T407  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T74 T407  65 1/1 assign qe = wr_en; Tests: T26 T74 T407  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 T74 T158 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_miodio_2
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T74,T407

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_2_miodio_2
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T74,T407
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T74,T407
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_mode_3
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T160  65 1/1 assign qe = wr_en; Tests: T74 T407 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T74 T160 T408 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_mode_3
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_mode_3
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T160
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_filter_3
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T160  65 1/1 assign qe = wr_en; Tests: T74 T407 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T407 T161 T434 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_filter_3
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_filter_3
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T160
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_miodio_3
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T74 T407 T160  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T74 T407 T160  65 1/1 assign qe = wr_en; Tests: T74 T407 T160  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T160 T408 T161 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_miodio_3
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT74,T407,T160

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_3_miodio_3
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T74,T407,T160
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T74,T407,T160
0 0 Covered T1,T2,T3

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%