Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_mode_4
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T4 T64 T163
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T4 T64 T163
65 1/1 assign qe = wr_en;
Tests: T4 T64 T163
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T398 T403
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_mode_4
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T4,T64,T163 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_mode_4
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T4,T64,T163 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T4,T64,T163 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_filter_4
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T4 T64 T163
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T4 T64 T163
65 1/1 assign qe = wr_en;
Tests: T4 T64 T163
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T398
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_filter_4
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T4,T64,T163 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_filter_4
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T4,T64,T163 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T4,T64,T163 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_miodio_4
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T4 T64 T163
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T4 T64 T163
65 1/1 assign qe = wr_en;
Tests: T4 T64 T163
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T4 T64 T398
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_miodio_4
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T4,T64,T163 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_4_miodio_4
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T4,T64,T163 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T4,T64,T163 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_mode_5
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T65 T66 T67
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T65 T66 T67
65 1/1 assign qe = wr_en;
Tests: T65 T66 T67
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T83
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_mode_5
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T65,T66,T67 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_mode_5
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T65,T66,T67 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T65,T66,T67 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_filter_5
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T65 T66 T67
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T65 T66 T67
65 1/1 assign qe = wr_en;
Tests: T65 T66 T67
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T83 T398 T399
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_filter_5
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T65,T66,T67 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_filter_5
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T65,T66,T67 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T65,T66,T67 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_miodio_5
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T65 T66 T67
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T65 T66 T67
65 1/1 assign qe = wr_en;
Tests: T65 T66 T67
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T57 T163 T167
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_miodio_5
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T65,T66,T67 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_5_miodio_5
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T65,T66,T67 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T65,T66,T67 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_mode_6
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T167 T166
65 1/1 assign qe = wr_en;
Tests: T163 T167 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T166 T400
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_mode_6
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_mode_6
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_filter_6
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T167 T166
65 1/1 assign qe = wr_en;
Tests: T163 T167 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T166 T426
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_filter_6
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_filter_6
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_miodio_6
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T167 T166
65 1/1 assign qe = wr_en;
Tests: T163 T167 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T424 T429
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_miodio_6
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_6_miodio_6
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_mode_7
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T167 T399 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T167 T399 T166
65 1/1 assign qe = wr_en;
Tests: T167 T399 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T167 T399 T166
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_mode_7
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T167,T399,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_mode_7
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T167,T399,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T167,T399,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_filter_7
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T167 T399 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T167 T399 T166
65 1/1 assign qe = wr_en;
Tests: T167 T399 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T399 T166 T424
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_filter_7
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T167,T399,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_filter_7
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T167,T399,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T167,T399,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_miodio_7
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T167 T399 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T167 T399 T166
65 1/1 assign qe = wr_en;
Tests: T167 T399 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T399 T400 T424
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_miodio_7
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T167,T399,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_7_miodio_7
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T167,T399,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T167,T399,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_0
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T398
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T167 T398
65 1/1 assign qe = wr_en;
Tests: T163 T167 T398
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T398
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_0
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T398 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_0
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T398 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T398 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_1
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T79 T163 T167
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T79 T401 T402
65 1/1 assign qe = wr_en;
Tests: T79 T401 T402
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T79 T163 T167
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_1
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T79,T401,T402 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_1
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T79,T401,T402 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T79,T163,T167 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_2
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T398
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T167 T398
65 1/1 assign qe = wr_en;
Tests: T163 T167 T398
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T398
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_2
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T398 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_2
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T398 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T398 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_3
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T83 T398 T399
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T83 T398 T399
65 1/1 assign qe = wr_en;
Tests: T83 T398 T399
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T83 T398 T399
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_3
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T83,T398,T399 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_3
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T83,T398,T399 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T83,T398,T399 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_4
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T167 T166
65 1/1 assign qe = wr_en;
Tests: T163 T167 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T166
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_4
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_4
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_5
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T83
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T167 T83
65 1/1 assign qe = wr_en;
Tests: T163 T167 T83
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T83
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_5
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T83 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_5
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T83 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T83 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_6
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T166 T403
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T163 T166 T403
65 1/1 assign qe = wr_en;
Tests: T163 T166 T403
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T166 T403
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_6
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T166,T403 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_6
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T166,T403 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T166,T403 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_7
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T167 T399 T166
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T167 T399 T166
65 1/1 assign qe = wr_en;
Tests: T167 T399 T166
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T167 T399 T166
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_7
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T167,T399,T166 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_cnt_th_7
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T167,T399,T166 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T167,T399,T166 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_0
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T6 T26 T53
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T6 T26 T53
65 1/1 assign qe = wr_en;
Tests: T6 T26 T53
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T6 T26 T53
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_0
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T6,T26,T53 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_0
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T6,T26,T53 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T6,T26,T53 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_1
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T398
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T84 T85 T86
65 1/1 assign qe = wr_en;
Tests: T84 T85 T86
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T398
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_1
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T553,T163,T167 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_1
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T553,T163,T167 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T398 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_2
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T398
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T84 T85 T86
65 1/1 assign qe = wr_en;
Tests: T84 T85 T86
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T398
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_2
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T398 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_2
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T398 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T398 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_3
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T83
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T84 T85 T86
65 1/1 assign qe = wr_en;
Tests: T84 T85 T86
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T83
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_3
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T83 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_3
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T83 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T83 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_4
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T4 T64 T163
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T4 T64 T84
65 1/1 assign qe = wr_en;
Tests: T4 T64 T84
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T4 T163 T167
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_4
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T4,T64,T163 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_4
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T4,T64,T163 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T4,T64,T163 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_5
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T65 T66 T67
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T65 T66 T67
65 1/1 assign qe = wr_en;
Tests: T65 T66 T67
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T65 T66 T67
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_5
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T65,T66,T67 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_5
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T65,T66,T67 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T65,T66,T67 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_6
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T163 T167 T398
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T84 T85 T86
65 1/1 assign qe = wr_en;
Tests: T84 T85 T86
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T163 T167 T398
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_6
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T163,T167,T398 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_6
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T163,T167,T398 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T163,T167,T398 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_7
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T167 T83 T399
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T84 T85 T86
65 1/1 assign qe = wr_en;
Tests: T84 T85 T86
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T167 T83 T399
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_7
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T167,T83,T399 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_detector_padsel_7
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T167,T83,T399 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T167,T83,T399 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_0
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 7 | 100.00 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 1 | 100.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T6 T26 T65
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T6 T26 T65
65 1/1 assign qe = wr_en;
Tests: T6 T26 T65
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 1/1 assign qs = q;
Tests: T6 T26 T53
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_0
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T6,T26,T65 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_0
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T6,T26,T65 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T6,T26,T65 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_1
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 6 | 85.71 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 0 | 0.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T6 T26 T65
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T6 T26 T65
65 1/1 assign qe = wr_en;
Tests: T6 T26 T65
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 0/1 ==> assign qs = q;
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_1
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T6,T26,T65 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_1
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T6,T26,T65 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T6,T26,T65 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_2
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 6 | 85.71 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 0 | 0.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T6 T26 T65
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T6 T26 T65
65 1/1 assign qe = wr_en;
Tests: T6 T26 T65
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 0/1 ==> assign qs = q;
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_2
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T6,T26,T65 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_2
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T6,T26,T65 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T6,T26,T65 |
0 |
0 |
Covered |
T1,T2,T3 |
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_3
| Line No. | Total | Covered | Percent |
TOTAL | | 7 | 6 | 85.71 |
ALWAYS | 56 | 4 | 4 | 100.00 |
CONT_ASSIGN | 64 | 1 | 1 | 100.00 |
CONT_ASSIGN | 65 | 1 | 1 | 100.00 |
CONT_ASSIGN | 72 | 1 | 0 | 0.00 |
55 always_ff @(posedge clk_i or negedge rst_ni) begin
56 1/1 if (!rst_ni) begin
Tests: T1 T2 T3
57 1/1 q <= RESVAL;
Tests: T1 T2 T3
58 1/1 end else if (wr_en) begin
Tests: T1 T2 T3
59 1/1 q <= wr_data;
Tests: T6 T26 T65
60 end
MISSING_ELSE
61 end
62
63 // feed back out for consolidation
64 1/1 assign ds = wr_en ? wr_data : qs;
Tests: T6 T26 T65
65 1/1 assign qe = wr_en;
Tests: T6 T26 T65
66
67 if (SwAccess == SwAccessRC) begin : gen_rc
68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW
69 // but the register is cleared to 0. See #5416 for a discussion.
70 assign qs = de && we ? d : q;
71 end else begin : gen_no_rc
72 0/1 ==> assign qs = q;
Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_3
| Total | Covered | Percent |
Conditions | 2 | 2 | 100.00 |
Logical | 2 | 2 | 100.00 |
Non-Logical | 0 | 0 | |
Event | 0 | 0 | |
LINE 64
EXPRESSION (wr_en ? wr_data : qs)
--1--
-1- | Status | Tests |
0 | Covered | T1,T2,T3 |
1 | Covered | T6,T26,T65 |
Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_wkup_cause_cause_3
| Line No. | Total | Covered | Percent |
Branches |
|
5 |
5 |
100.00 |
TERNARY |
64 |
2 |
2 |
100.00 |
IF |
56 |
3 |
3 |
100.00 |
64 assign ds = wr_en ? wr_data : qs;
-1-
==>
==>
Branches:
-1- | Status | Tests |
1 |
Covered |
T6,T26,T65 |
0 |
Covered |
T1,T2,T3 |
56 if (!rst_ni) begin
-1-
57 q <= RESVAL;
==>
58 end else if (wr_en) begin
-2-
59 q <= wr_data;
==>
60 end
MISSING_ELSE
==>
Branches:
-1- | -2- | Status | Tests |
1 |
- |
Covered |
T1,T2,T3 |
0 |
1 |
Covered |
T6,T26,T65 |
0 |
0 |
Covered |
T1,T2,T3 |