dashboard | hierarchy | modlist | groups | tests | asserts

Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_21

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_22

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_23

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_24

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_25

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_26

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_27

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_28

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_29

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_30

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_31

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_32

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_33

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_34

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_35

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_36

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_37

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_38

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_39

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_40

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_41

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_42

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_43

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_44

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_45

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_46

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_0

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_1

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_2

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_3

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_4

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00


Module Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_5

Instance :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Instance's subtree :
SCORELINECONDTOGGLEFSMBRANCHASSERT
100.00 100.00 100.00 100.00


Parent :
SCORELINECONDTOGGLEFSMBRANCHASSERTNAME
99.26 99.77 97.26 100.00 100.00 u_reg


Subtrees :
NAMESCORELINECONDTOGGLEFSMBRANCHASSERT
wr_en_data_arb 100.00 100.00 100.00 100.00

Go back
Module Instances:
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_21
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_22
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_23
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_24
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_25
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_26
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_27
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_28
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_29
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_30
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_31
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_32
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_33
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_34
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_35
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_36
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_37
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_38
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_39
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_40
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_41
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_42
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_43
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_44
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_45
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_46
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_0
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_1
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_2
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_3
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_4
tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_5
Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_21
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T170 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_21
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_21
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_22
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T182 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_22
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_22
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_23
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T182 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_23
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T448,T178

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_23
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T448,T178
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_24
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T183 T170 T174 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_24
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_24
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_25
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T183 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_25
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_25
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_26
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T417 T396 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_26
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_26
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_27
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T182 T170 T175 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_27
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_27
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_28
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T170 T174 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_28
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_28
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_29
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T170 T174 T175 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_29
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_29
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_30
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T183 T174 T175 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_30
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T99,T178

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_30
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T99,T178
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_31
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T178 T182 T175 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_31
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_31
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_32
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T182 T183 T170 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_32
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_32
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_33
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T417 T396 T171 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_33
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T445,T178

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_33
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T445,T178
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_34
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T182 T183 T175 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_34
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_34
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_35
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T182 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_35
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T432

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_35
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T432
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_36
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T178 T182 T170 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_36
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_36
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_37
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T183 T170 T174 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_37
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_37
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_38
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T178 T183 T170 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_38
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_38
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_39
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T178 T170 T174 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_39
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T540,T178

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_39
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T540,T178
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_40
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T182 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_40
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_40
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_41
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T182 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_41
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T448,T178

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_41
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T448,T178
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_42
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T178 T182 T183 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_42
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_42
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_43
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T182 T170 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_43
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_43
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_44
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T183 T170 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_44
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_44
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_45
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T35 T178 T170 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_45
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T182

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_45
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T182
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_46
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T35 T178 T182  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T35 T94 T95  65 1/1 assign qe = wr_en; Tests: T35 T94 T95  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T178 T182 T183 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_46
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT35,T178,T432

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_regwen_46
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T35,T178,T432
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T35,T178,T182
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_0
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T27 T10  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T27 T10  65 1/1 assign qe = wr_en; Tests: T26 T27 T10  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 T27 T39 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_0
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T27,T10

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_0
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T27,T10
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T27,T10
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_1
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T27 T38  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T27 T38  65 1/1 assign qe = wr_en; Tests: T26 T27 T38  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 T27 T38 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_1
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T27,T38

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_1
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T27,T38
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T27,T38
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_2
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T27 T70  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T27 T70  65 1/1 assign qe = wr_en; Tests: T26 T27 T70  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 T27 T70 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_2
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T27,T70

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_2
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T27,T70
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T27,T70
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_3
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T27 T39  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T27 T39  65 1/1 assign qe = wr_en; Tests: T26 T27 T39  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 T27 T39 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_3
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T27,T39

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_3
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T27,T39
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T27,T39
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_4
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T27 T10  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T27 T10  65 1/1 assign qe = wr_en; Tests: T26 T27 T10  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 T27 T39 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_4
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T27,T10

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_4
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T27,T10
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T27,T10
0 0 Covered T1,T2,T3

Line Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_5
Line No.TotalCoveredPercent
TOTAL77100.00
ALWAYS5644100.00
CONT_ASSIGN6411100.00
CONT_ASSIGN6511100.00
CONT_ASSIGN7211100.00

55 always_ff @(posedge clk_i or negedge rst_ni) begin 56 1/1 if (!rst_ni) begin Tests: T1 T2 T3  57 1/1 q <= RESVAL; Tests: T1 T2 T3  58 1/1 end else if (wr_en) begin Tests: T1 T2 T3  59 1/1 q <= wr_data; Tests: T26 T27 T63  60 end MISSING_ELSE 61 end 62 63 // feed back out for consolidation 64 1/1 assign ds = wr_en ? wr_data : qs; Tests: T26 T27 T63  65 1/1 assign qe = wr_en; Tests: T26 T27 T63  66 67 if (SwAccess == SwAccessRC) begin : gen_rc 68 // In case of a SW RC colliding with a HW write, SW gets the value written by HW 69 // but the register is cleared to 0. See #5416 for a discussion. 70 assign qs = de && we ? d : q; 71 end else begin : gen_no_rc 72 1/1 assign qs = q; Tests: T26 T27 T63 

Cond Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_5
TotalCoveredPercent
Conditions22100.00
Logical22100.00
Non-Logical00
Event00

 LINE       64
 EXPRESSION (wr_en ? wr_data : qs)
             --1--
-1-StatusTests
0CoveredT1,T2,T3
1CoveredT26,T27,T63

Branch Coverage for Instance : tb.dut.top_earlgrey.u_pinmux_aon.u_reg.u_mio_outsel_5
Line No.TotalCoveredPercent
Branches 5 5 100.00
TERNARY 64 2 2 100.00
IF 56 3 3 100.00


64 assign ds = wr_en ? wr_data : qs; -1- ==> ==>

Branches:
-1-StatusTests
1 Covered T26,T27,T63
0 Covered T1,T2,T3


56 if (!rst_ni) begin -1- 57 q <= RESVAL; ==> 58 end else if (wr_en) begin -2- 59 q <= wr_data; ==> 60 end MISSING_ELSE ==>

Branches:
-1--2-StatusTests
1 - Covered T1,T2,T3
0 1 Covered T26,T27,T63
0 0 Covered T1,T2,T3

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%